CGPNL - SANIZIDE GERMICIDAL SOLUTION

  • MSDS: CGPNL
  • Manufacturer: SAFETEC OF AMERICA INC
  • Product Name: SANIZIDE GERMICIDAL SOLUTION
  • National Stock Number: 6840-00N083074
Product Identification

Product ID:SANIZIDE GERMICIDAL SOLUTION
MSDS Date:02/17/1997
FSC:6840
NIIN:00N083074
MSDS Number: CGPNL

Responsible Party
SAFETEC OF AMERICA INC
1055 EAST DELAVAN AVE
BUFFALO, NY 14215
US

Emergency Phone: 800-255-3924

Info Phone: 716-895-1822

Cage: SAFTC

Contractor
SAFETEC OF AMERICA INC
UNKNOW NORTH TONAWANDA, NY 14120 US

Telephone: 800-456-7077

Cage: 00K94

Ingredients

ISOPROPYL ALCOHOL (SARA 313)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 8.0%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500 STEL


N-ALKYL DIMETHYLBENZYL AMMONIUM CHLORIDE; LD50 (ORAL RAT)

CAS: 68391-01-5

Fraction By Weight: 0.14%

OSHA PEL N/K

ACGIH TLV: N/K


QUARTERNARY AMMONIUM CHLORIDE;

CAS: 68956-79-6

Fraction By Weight: 0.14%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CAUSES TEMPORARY EYE
IRRITATION. IF INGESTED, CAN CAUSE GASTROINTESTINAL IRRITATION,
NAUSEA, VOMITING AND DIARRHEA.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:PROLONGED OR REPEATED CONTACT MAY CAUSE SKIN
IRRITATION TO HIGHLY SENSITIVE SKIN.
Medical Cond Aggravated by Exposure:DERMATITIS.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. CONSULT MEDICAL PERSONNEL. SKIN: WASH THOROUGHLY
WITH SOAP AND WATER. IF IRRITATION PERSISTS, CONSULT MEDICAL
PERSONNEL. IN GESTION: GIVE 2 GLASSES OF MILK OR WATER. INDUCE
VOMITING. GET MEDICAL ATTENTION. INHALATION: REMOVE TO FRESH AIR,
GET MEDICAL ATTENTION IF REQUIRED.

Fire Fighting

Flash Point Method:TOC
Flash Point:124F,51C
Lower Limits:2.0%
Upper Limits:12%
Extinguishing Media:USE ALCOHOL FOAM, CARBON DIOXIDE, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . FOLLOW NIOSH RECOMMENDED GUIDELINES FOR ALCOHOLIC
FIRES.
Unusual Fire/Explosion Hazard:VAPORS CAN BE HEAVIER THAN AIR. NEVER USE
TORCH OR OTHER SOURCES OF FLAME NEAR PRODUCT.

Accidental Release

Spill Release Procedures:PROVIDE ADEQUATE VENTILATION. ABSORB SPILLED
LIQUID WITH VERMICULITE, FLOOR ABSORBENT OR OTHER MATERIAL AND
TRANSFER TO HOOD.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER(S) TIGHTLY SEALED WHEN
NOT IN USE. STORE IN A COOL, DRY AREA AWAY FROM ANY SOURCES OF
IGNITION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:ORDINARILY, NONE REQUIRED. USE NIOSH APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:198F,92C
Vapor Density:<1
Spec Gravity:0.999 (H*2O=1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID; ALCOHOLIC ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION WILL GENERATE
OXIDES OF CARBON.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.